Heating and Air Conditioning: Specifications
Refrigerant Capacity 0.794 kg (28 oz or 1.75 lb)Refrigerant Oil Capacity
- A/C System = 150 ml (5.00 oz)
- Condenser = 30 ml (1.00 oz)
- Evaporator = 59 ml (2.00 oz)
- Filter/Drier = 30 ml (1.00 oz)
- Line blown = 44 ml (1.50 oz)
- Compressor -- Most reclaim/recycling equipment will measure the lubricant being removed. This is the amount of lubricant to be added back to the system. If a new compressor is being installed, drain lubricant from old compressor, measure the amount drained and discard old lubricant. Drain the lubricant from the new compressor into a clean container. Return the amount of lubricant measured from the old compressor, plus the amount reclaimed from the system back into the new compressor.