1, 2 and 3 Digit Codes: 74
CODE NUMBERScan tool: 74
General scan tool: P1799
CODE NAME
Calculated oil temperature in use
CODE DESCRIPTION
This code will set when the Transaxle Thermistor Voltage is below 0.0784 volts or above 4.9412 volts for 15 seconds, for 3 consecutive engine starts.
PROBABLE CAUSE
- Malfunction of oil temperature sensor
- Harness or connector between transaxle range sensor and TCM open or short-circuited
- Malfunction of TCM
DIAGNOSTIC CHART