1, 2 and 3 Digit Codes: 33
CODE NUMBERScan tool: 33
General scan tool: P1789
CODE NAME
Hydraulic pressure switch: OD/2-4
CODE DESCRIPTION
Pressure switch falls to respond within specified time for given temperature range.
PROBABLE CAUSE
- Low/high fluid level in transaxle
- Malfunction of pressure switch assembly
- Internal transaxle problem
SERVICE PROCEDURE
- Carry out the inspection procedure for code No. 31.