Positive Crankcase Ventilation: Testing and Inspection
CRANKCASE VENTILATION SYSTEM INSPECTION
1. Remove the rocker cover side of the PCV valve hose.
2. Start the engine and run at idle.
3. Place a finger at the opening of the PCV valve and confirm that vacuum of the intake manifold is felt.
NOTE: At this time, the plunger in the PCV valve moves forward and backward.
4. If vacuum is not felt, replace the PCV valve.