Engine Mangement
Trouble Code Number- Scan tool 71
- General Scan Tool (None listed)
- MIL 44
Fault Message
- Battery Temperature Sensor Volts Out of Limit
Background
- Battery temperature input is used to adjust the generator charging rate based upon the ambient temperature around the battery.
Range of Check
- Ignition switch: ON
Set Condition
- The sensor voltage is not within the acceptable range of 0.3 to 4.9 volts for 3 seconds or more.
Probable Cause
- Battery temperature sensor failed
- PCM failed
Recommended Action
- Replace the PCM.