Manifold Pressure/Vacuum Sensor: Service and Repair
Fig. 14 Temperature Sensor And MAP Sensor:
The MAP sensor attaches to the intake manifold plenum Fig. 14.
REMOVAL
1. Disconnect the electrical connector from the MAP sensor.
2. Remove sensor mounting screws.
3. Remove sensor.
INSTALLATION
1. Insert sensor into intake manifold while making sure not to damage 0-ring seal.
2. Tighten mounting screws to 2 Nm (20 in. lbs) torque.
3. Attach electrical connector to sensor.