Diagnostic Procedures
Before beginning sunroof diagnostics verify that all other power accessories are in proper operating condition. If not, a common electrical problem may exist. Check the condition of the circuit protection (20 amp circuit breaker in cavity 19 of the junction block). Inspect all wiring connector pins for proper engagement and continuity. Check for battery voltage at the power sunroof controller. If battery voltage of more than 10 volts is detected at the controller, proceed with the following tests (the controller will not operate at less than 10 volts).Before beginning diagnosis for wind noise or water leaks, verify that the problem was not caused by releasing the control switch before the was sunroof fully closed. The sunroof module has a water-management system. During washing high-pressure water may be forced between the glass panel seal and the roof opening. Normally this water will drain. However, when a blower-type drying system is used, like those found in automatic car washes, the water may not have a chance to drain before the blower forces air between the seal and the roof opening. This causes the water to blow over the edge of the module and onto the headlining.