Fault Code 3
If both codes 2 and 3 appear at the same time, proceed with both tests. There is usually only one failure.1. Remove terminal #5 from the 21-way Control Module connector and retest the system.
NOTE: This may cause other codes to be generated. These codes should be disregarded at this time.
- If code 3 reappears, replace the Control Module.
- If code 3 does not reappear, go to step 2.
2. Remove the 21-way Control Module connector and check for continuity between terminal #5 and ground.
- If there is continuity, repair the wiring.
- If there is no continuity, go to step 3.
3. Check for resistance between terminals #5 and #4. Resistance should be between 20 and 50 ohms.
- If resistance is incorrect, replace the blend door actuator.