Brake Fluid Pressure Sensor/Switch: Description and Operation
Early Production ABS OperationHydraulic Assembly:
The control pressure switch is attached to the valve block and provides an electrical signal to the Anti-lock Brake Control Module (ABM) when boost pressure reaches approximately 400 psi. This ABCM uses the signal for verifying proper operation of the booster/master cylinder. A two pin connector and short harness are used to connect the control pressure switch to the sensor block. The control pressure switch is a serviceable part.