15B Auto Shutdown Relay Pull-In Coil Circuit
12-way Power Module Pin Connector:
1. Turn ignition switch Off, then disconnect 12-way connector from [1][2]power module.
2. Connect a voltmeter between pin 5 of [1][2]power module and ground, then turn ignition switch to Run position.
3. If voltmeter reads within one volt of battery voltage, locate and repair open or short in wire from cavity 5.
CAUTION: Check the terminal in cavity No. 12 of the 12-way to make sure it is not spread apart causing a poor connection.
4. If voltmeter reads 0---1 volt, replace [1][2]power module.