11C Injector 3 & 4 Wires to Power Module
10-way Power Module Connector:
1. Turn ignition switch Off, then disconnect [1][2]power module 10-way connector.
2. Connect an ohmmeter between cavities 6 and 7 of connector.
3. If ohmmeter indicates continuity, proceed to Test 11 step D.
4. If ohmmeter does not indicate continuity, locate and repair open in circuit from cavity 6 or 7.