DR-20E Calibration Battery Temperature Sensor
1. With diagnostic read-out tool connected to engine test connector and engine warm, place system into sensor test mode 01. Display reading must be divided by ten to determine actual reading.
2. If display indicates .2---2.5 volts, proceed to Test 21.
3. If display does not indicate .2---2.5 volts, replace power module.