DR-16C Battery Temperature Sensor Wire
1. Disconnect power module 12 way electrical connector, then connect an ohmmeter between terminals No. 3 and 12 of the power module.
2. If ohmmeter indicates some resistance, check wiring from power module 12 way electrical connector terminal No. 3 for an open circuit.
3. If ohmmeter indicates no resistance or an open circuit, replace power module.