Radio - Poor Reception/Noise/Interference
87chrysler13Models
1985-1986 Lancer/ LeBaron GTS
1987 Sundance/ Shadow
Subject
Poor Radio Reception or Noise in AM and/or FM Mode Due to Blower Motor
Index
ELECTRICAL
Date
February 2, 1987
No..
08-02-87 (C1-08)
P-0223
SYMPTOM/CONDITION
Vehicles may experience poor radio reception or noise in AM and/or FM mode.
DIAGNOSIS
To determine if noise is due to blower motor, turn key to ignition on with engine not running. Turn blower on to the third or fourth speed. Turn radio on and tune to a weak AM or FM station which exhibits noise. Turn blower off and if noise is not present anymore, proceed to repair procedure.
PARTS REQUIRED
Blower Motor Noise Suppression Package PN 4443154
Consists of:
1 Capacitor Assembly - A/C Blower Motor PN 4443174
1 Self-Piercing Screw PN 6032473
REPAIR PROCEDURE
This repair advises the technician to install a capacitor assembly at the logic module.
1. Disconnect battery.
2. Remove glove box assembly.
3. Remove logic module per service manual procedures.
FIGURE 1:
4. Lancer/LeBaron GTS Only
a. Punch or drill (with a #31 drill) a 3 mm hole on the right kick plate area (Figure 1).
FIGURE 2:
b. Align capacitor assembly, PN 4443174, on right side kick area and mount with the self-piercing screw, PN 6032473 (Figure 2).
c. Disconnect the existing blower motor pigtail from wiring harness. Then connect the wires from capacitor assembly to connectors from wiring harness and blower motor.
FIGURE 3:
5. Shadow/Sundance Only
a. Punch or drill (with a #31 drill) a 3 mm hole on the right kick plate area (Figure 3).
FIGURE 4:
b. Align capacitor assembly, PN 4443174, on right side kick area and mount with the self-piercing screw (Figure 4).
c. Disconnect the existing blower motor pigtail from wiring harness. Then connect the wires from capacitor assembly to connectors from wiring harness and blower motor.
6. Install logic module per service manual procedures.
7. Reinstall glove box assembly.
8. Reconnect battery.
9. Verify blower motor operation and perform diagnosis to assure proper installation.
POLICY: Reimbursable within the provisions of the warranty
TIME ALLOWANCE:
Labor Operation No. 08-60-02-93 . . . . . . . . . . . . . 0.5 Hrs.
FAILURE CODE: 68 - Noisy