DR-25 Checking Secondary Ignition System
This test must be performed with engine warm.
1. Connect suitable engine analyzer to engine, then start engine and let speed stabilize for two minutes.
2. Test secondary ignition according to equipment manufacturers instructions. Coil output should be at least 25,000 volts.
3. If secondary ignition system is good, proceed to Test 26.
4. If secondary ignition system is not good, repair as required.