DR-17C BARO Read Solenoid Circuit For Opens
1. Turn ignition switch Off, then disconnect baro read solenoid single and 4-way electrical connectors.
2. Connect an ohmmeter between blue wire terminal of single connector and light blue wire terminal of 4-way connector.
3. If ohmmeter indicates an open circuit, replace solenoid.
4. If ohmmeter shows some resistance, proceed to Test 17 step D.