DR-16D Wastegate Solenoid Circuit For Short
1. Disconnect solenoid 4-way electrical connector, then disconnect logic module red electrical connector.
2. Connect an ohmmeter between logic module red electrical connector terminal No. 19 and ground.
3. If ohmmeter does not indicate continuity, replace logic module.
CAUTION: Before replacing the logic module make sure the green wire of the solenoid harness is not shorted to ground.
4. If ohmmeter indicates continuity, check wiring from terminal 19 of logic module red electrical connector for short circuit to ground.