DR-16C Wastegate Solenoid Circuit For Open
1. Place ignition switch in Off position, then disconnect 4-way and single electrical connectors from wastegate solenoid.
2. Connect an ohmmeter between single connector blue wire and green wire of 4-way connector.
3. If ohmmeter indicates resistance, proceed to Test 16 step D.
4. If ohmmeter indicates an open circuit, replace solenoid.