Service Port HVAC: Service and Repair
Service Ports Replacement
Tools Required
* J 39400-A - Halogen Leak Detector
* J 46246 - Valve Core Removal Tool
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging Refrigerant Recovery and Recharging.
2. Use J 46246 - valve core removal tool or equivalent to remove the valve core.
Installation Procedure
1. Use J 46246 - valve core removal tool or equivalent to install and tighten the valve core.
2. Evacuate and charge the A/C system. Refer to Refrigerant Recovery and Recharging Refrigerant Recovery and Recharging.
Important: To prevent loss of refrigerant charge, tighten the cap. Replace the cap if the seal is missing or damaged.
3. Test the affected A/C fittings for leaks using J 39400-A - halogen leak detector.