Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake




Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake

Removal Procedure




1. Disconnect the engine wiring harness electrical connector (8) from the bank 1 intake CMP actuator solenoid valve.




2. Remove the CMP actuator solenoid valve bolt and valve (2).

3. Inspect the CMP actuator solenoid valve seal and replace as necessary.

Installation Procedure




1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.

Caution: Refer to Fastener Caution Fastener Caution.

2. Install the CMP actuator solenoid valve (2) and bolt.

Tighten the bolt to 10 Nm (89 lb in).




3. Connect the engine wiring harness electrical connector (8) to the bank 1 intake CMP actuator solenoid valve.