B2545
DTC B2545
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptor
DTC B2545 00
-
Backup Lamps Circuit
Diagnostic Fault Information
Circuit/System Description
When the PRNDL is placed in the REVERSE position, a signal is sent to the body control module (BCM). The BCM then applies voltage through the backup lamps control circuit to the back up lamps. The engine may need to be running for the backup lamps to function.
Conditions for Running the DTC
* The ignition is ON.
* The back up lamps must be commanded ON.
Conditions for Setting the DTC
The BCM detects a short to ground on the back up lamp control circuit when the back up lamps are being commanded ON.
Action Taken When the DTC Sets
The back up lamps do not illuminate.
Conditions for Clearing the DTC
* The conditions for setting the DTC are no longer present.
* A history DTC clears after 100 malfunction-free ignition cycles.
Reference Information
Schematic Reference
Exterior Lights Schematics Exterior Lights Schematics
Connector End View Reference
Component Connector End Views A/C Compressor Clutch
Description and Operation
Exterior Lighting Systems Description and Operation Exterior Lighting Systems
Electrical Information Reference
* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs
Scan Tool Reference
Control Module References Programming and Relearning for scan tool information
Circuit/System Verification
Ignition ON, command the backup lamps ON and OFF with a scan tool. The backup lamps should turn ON and OFF when changing between the commanded states.
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the backup lamp.
2. Test for less than 5 ohms between the ground circuit terminal listed below and ground:
* RPO Z88 - terminal 1
* RPO WDA - terminal 2
* RPO W49/X88 - terminal B
• If greater than the specified range, test the ground circuit for an open/high resistance.
3. Connect a test lamp between the control circuit terminal listed below and the ground circuit terminal:
* RPO Z88 - terminal 2
* RPO WDA - terminal 1
* RPO W49/X88 - terminal A
4. Command the Backup Lamps ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
• If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
• If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
5. If all circuits test normal, test or replace the backup lamp.
Repair Instructions
Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.
* Backup Lamp Replacement Backup Lamp Replacement
* Backup Lamp Bulb Replacement (Acadia) Service and RepairBackup Lamp Bulb Replacement (Enclave) Service and RepairBackup Lamp Bulb Replacement (Traverse) Service and Repair
* Control Module References Programming and Relearning for BCM replacement, programming and setup