Low Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Low Pressure Switch Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Disconnect the low pressure switch electrical connector (2).
2. Remove the low pressure switch (1) from the accumulator.
3. Remove the O-ring seal.
Installation Procedure
1. Install the new O-ring seal to the switch.
Notice: Refer to Fastener Notice.
2. Install the A/C low pressure switch (1) to the accumulator.
Tighten the switch to 4 N.m (35 lb in).
3. Connect the low pressure switch electrical connector (2).
4. Leak test the fittings of the component using the J 39400-A.