FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Mode Actuator (With RPO Code D07)



MODE ACTUATOR REPLACEMENT (WITH RPO CODE D07)

REMOVAL PROCEDURE




1. Remove the floor air outlet duct extension (1) from the floor duct (2).
2. Remove the center console.
3. Remove the screws from the center console duct.
4. Remove the center console duct.




5. Disconnect the electrical connection from the mode actuator (10).




6. Remove the mode actuator mounting screws from the HVAC module.
7. Remove the mode actuator as an assembly with the actuator cam.

INSTALLATION PROCEDURE




1. Install the mode actuator as an assembly with the actuator cam.
- Line up the heater/defroster valve lever with the mode actuator cam slot.
- Line up the A/C valve lever with the mode actuator cam.
2. Install the mode actuator mounting screws to the HVAC module.

Tighten the screws to 1.6 N.m (14 lb in).

NOTE: Refer to Fastener Notice in Service Precautions.




3. Connect the electrical connection at the mode actuator (10).




4. Install the center console duct.
5. Install the screws to the center console duct.

Tighten the screws to 1.6 N.m (14 lb in).

6. Install the center console.
7. Install the floor air outlet duct extension (1) to the floor air duct (2).