Instrument Panel (I/P) Extension Trim Plate Replacement
INSTRUMENT PANEL (I/P) EXTENSION TRIM PLATE REPLACEMENT
REMOVAL PROCEDURE
1. Disable the SIR. Refer to SIR Disabling and Enabling Zone 5 in Restraint Systems.
CAUTION: Refer to SIR Caution in Service Precautions.
2. Remove the knee bolster trim panel.
3. Remove the instrument panel (I/P) upper trim pad.
4. Remove the nuts (2) retaining the I/P extension to HVAC duct.
5. Remove the screws (3) from the I/P extension.
6. Remove the I/P extension (1).
INSTALLATION PROCEDURE
1. Install the I/P extension (1) to the I/P.
2. Install the screws (3).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws (3) to 3 N.m (26 lb in).
3. Install the nuts (2) that retain the HVAC duct to the I/P extension.
Tighten the screws (2) to 3 N.m (26 lb in).
4. Install the I/P upper trim pad.
5. Install the knee bolster trim panel.
6. Enable the SIR. Refer to SIR Disabling and Enabling Zone 5 in Restraint Systems.