FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Blower Motor - Auxiliary (Without RPO Code E59)



BLOWER MOTOR REPLACEMENT - AUXILIARY (WITHOUT RPO CODE E59)

REMOVAL PROCEDURE
1. Remove the accessory panel.




2. Remove the screws from the hinged cover.
3. Remove the cover from the rear trim panel.
4. Release the tabs and pull out the trim panel.
5. Disconnect the auxiliary blower motor electrical connector.
6. Disconnect the auxiliary blower motor resistor electrical connector.
7. Disconnect the auxiliary air temperature actuator electrical connector.




8. Remove the auxiliary blower motor mounting screws.
9. Remove the auxiliary blower motor from the blower motor housing.

INSTALLATION PROCEDURE




1. Install the auxiliary blower motor to the blower motor housing.
2. Install the auxiliary blower motor mounting screws.

Tighten the screws to 1.6 N.m (14 lb in).

NOTE: Refer to Fastener Notice in Service Precautions.

3. Connect the auxiliary air temperature actuator electrical connector.
4. Connect the auxiliary blower motor resistor electrical connector.
5. Connect the auxiliary blower motor electrical connector.




6. Install the trim panel and press firmly into the tabs.
7. Align the cover and fasten the screws.

Tighten the screws to 2.5 N.m (22 lb in).

8. Install the accessory panel.