Generator Replacement
REMOVAL PROCEDURE1. Disconnect the negative battery cable.
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
2. Remove the air cleaner hose.
3. Remove the drive belt from the generator pulley.
4. Disconnect the power steering pressure switch connector.
5. Disconnect the generator electrical connector.
6. Remove the rubber protector, the nut and the electrical connector from the generator B+ terminal.
7. Remove the 2 vacuum lines from the top of the EVAP canister.
8. Slide the EVAP canister from the bracket on the inner fender and position aside.
9. Remove the upper and lower generator mounting bolts.
10. Remove the generator from the vehicle.
INSTALLATION PROCEDURE
1. Install the generator to the vehicle. Secure the generator with the upper and lower mounting bolts.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the generator mounting bolts to 23 N.m (17 lb ft).
2. Connect the electrical connector to the generator B+ terminal. Secure the connector with one nut and the rubber protector.
Tighten
Tighten the electrical connector nut to 10 N.m (89 lb in).
3. Connect the generator electrical connector.
4. Connect the power steering pressure switch connector.
5. Slide the EVAP canister into the bracket on the inner fender.
6. Connect the 2 vacuum lines to the top of the EVAP canister.
7. Install the drive belt to the generator pulley.
8. Install the air cleaner hose.
9. Connect the negative battery cable.
Tighten
Tighten the negative battery cable-to-negative battery terminal retainer to 15 N.m (11 lb ft).