High Pressure Sensor / Switch: Service and Repair
HVAC SYSTEM - AUTOMATIC
REMOVAL PROCEDURE
1. Disconnect the A/C compressor refrigerant pressure switch connection.
2. Remove the A/C compressor refrigerant pressure switch.
INSTALLATION PROCEDURE
IMPORTANT: Counterhold the compressor/condenser hose using a wrench.
1. Install the A/C compressor refrigerant pressure switch:
^ Use new O-rings.
^ Lubricate the new O-rings using mineral oil, 525 viscosity.
Tighten
Tighten the sensor to 7 N.m (62 lb in).
2. Connect the A/C compressor refrigerant pressure switch connector.