Heating and Ventilation
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution In Service Precautions.
1. Disconnect the negative battery cable.
2. Disconnect the electrical connector (3).
3. Remove the blower motor resistor mounting screws (1).
4. Remove the blower motor resistor (2) from the blower case.
INSTALLATION PROCEDURE
1. Install the blower motor resistor (2) to the blower case.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the blower motor resistor mounting screws (1).
Tighten
Tighten the screws to 1.9 N.m (17 lb in).
3. Connect the electrical connector (3).
4. Connect the negative battery cable.
5. Perform the heater function test. Refer to Function Test. Testing and Inspection