Blower Motor Resistor Replacement - Auxiliary
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the negative battery cable.
2. Remove the left rear quarter trim panels.
3. Disconnect the electrical connector from the resistor.
4. Remove the retaining screws.
5. Remove the resistor from the blower case.
INSTALLATION PROCEDURE
1. Install the resistor into the blower case.
2. Install the retaining screws.
3. Connect the electrical connector to the resistor.
4. Install the left rear quarter trim panels.
5. Connect the negative battery cable.