FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P0D43




DTC P0D43-P0D45

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructionsprovides an overview of each diagnostic category.

DTC Descriptors
DTC P0D43
- Battery Charger 14V Output Voltage Sensor Performance

DTC P0D44
- Battery Charger 14V Output Voltage Sensor Circuit Low Voltage

DTC P0D45
- Battery Charger 14V Output Voltage Sensor Circuit High Voltage

Circuit/System Description

The battery charger will diagnose its own systems and determine when a fault condition is present. Diagnostics and system status is communicated from the battery charger to the hybrid/EV powertrain control module 2 through serial data. The hybrid/EV powertrain control module 2 is the host controller for DTC information.

The battery charger takes internal measurements that verify the charger is performing properly. The battery charger measures internal voltages, currents, and temperatures and verifies they are within the proper range.

Conditions for Running the DTC

The vehicle needs to be connected to an AC supply and the battery charger is charging the vehicle.

Conditions for Setting the DTC

The battery charger output voltage is outside expected range.

Action Taken When the DTC Sets

* DTC P0D43-P0D44 are type A DTCs.
* Disables high voltage battery charging.

Conditions for Clearing the DTC

DTC P0D43-P0D44 are type A DTCs.

Diagnostic Aids

External battery chargers can cause this DTC to set. Ensure customer did not have an external battery charger connected to vehicle during plug-in charging attempt.

Reference Information
Schematic Reference

Plug-In Charging Schematics Plug-In Charging Schematics
Connector End View Reference

Component Connector End Views Hybrid/EV Battery Pack X1
Description and Operation

Plug-In Charging System Description and Operation Description and Operation
Electrical Information Reference

* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference

Control Module References Programming and Relearningfor scan tool information
Special Tools

EL-48900 - HEV Safety Kit

For equivalent regional tools, refer to Special Tools Tools and Equipment.

Circuit/System Testing

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.


The High Voltage Disabling procedure will perform the following tasks:


* Identify how to disable high voltage.

* Identify how to test for the presence of high voltage.

* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.


Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:


* Safety glasses with appropriate side shields when within 15 meters (50 feet) of the vehicle, either indoors or outdoors.

* Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.


- Visually and functionally inspect the gloves before use.

- Wear the Insulation gloves with leather protectors at all times when working with the high voltage battery assembly, whether the system is energized or not.


Failure to follow the procedures exactly as written may result in serious injury or death.


1. Vehicle OFF, disable the high voltage at the T18 battery charger. Refer to High Voltage Disabling High Voltage Disabling. Disconnect the X1 harness connector at the T18 battery charger.
2. Vehicle ON, test for B+ between the IGN circuit terminal A and ground.

If less than the specified range, test the B+ circuit for a short to ground or an open/high resistance.

3. If all circuits test normal, replace the T18 battery charger.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.

Control Module References Programming and Relearningfor battery charger replacement, programming and setup