Generator Brace Replacement
REMOVAL PROCEDURE1. Loosen the generator pivot bolt (1).
2. Remove the generator rear brace nut (4).
3. Remove the generator rear brace.
INSTALLATION PROCEDURE
1. Install the generator rear brace.
2. Install the generator pivot bolt (1).
3. Install the generator rear brace nut (4).
4. Tighten the generator bolt and nut in the following sequence:
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
1. Tighten the generator pivot bolt (1) to 50 N.m (37 lb ft).
2. Tighten the generator rear brace nut (4) to 25 N.m (18 lb ft).