Disconnect/Connect Procedure
BATTERY NEGATIVE CABLE DISCONNECT/CONNECT PROCEDUREREMOVAL PROCEDURE
CAUTION:
- Refer to SIR Caution in Service Precautions.
- Refer to Battery Disconnect Caution in Service Precautions.
1. Turn OFF all the lamps and the accessories.
2. Place the ignition switch in the OFF position.
3. Disconnect the battery negative cable from the battery.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
IMPORTANT: Clean any existing oxidation from the contact face of the battery terminal and battery cable using a wire brush before installing the battery cable to the battery terminal.
1. Connect the battery negative cable to the battery.
Tighten the bolts to 15 N.m (11 lb ft).