Lamp Control Module: Service and Repair
LAMP CONTROL MODULE REPLACEMENTREPLACEMENT PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
Battery Disconnect Caution
1. Disconnect the negative battery cable.
2. Remove the instrument panel low cover.
3. Remove the screws and the lamp control module.
4. Disconnect the electrical connector.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
Fastener Notice
1. Install the lamp control module with the screws.
2. Connect the electrical connector.
3. Install the instrument panel low cover.
4. Connect the negative battery cable.