Resonator: Service and Repair
REMOVAL PROCEDURE
1. Remove the Mass Air Flow (MAF) sensor (10).
2. Remove the intake resonance switchover valve assembly (3).
3. Disconnect the switchover valves solenoid electrical connector.
4. Disconnect the vacuum connections at the switchover valve solenoid and the vacuum reservoir (4).
5. Remove and discard the cable tie that retains the vacuum lines.
6. Remove the intake air resonator (7).
INSTALLATION PROCEDURE
1. Install the intake air resonator.
2. Insert the intake air resonator guide pin into the rubber mount (8).
3. Connect the vacuum connections at the switchover valve and the vacuum tank.
4. Install a new cable tie to retain the vacuum lines.
5. Connect the electrical connector to the switchover valve.
6. Install the intake resonance switchover valve assembly.
7. Install the Mass Air Flow (MAF) sensor.