Compressor Control Valve Assembly Install
TOOLS REQUIREDJ 5403 Snap Ring Pliers
1. Coat the O-rings with 525 viscosity refrigeration oil.
2. Using thumb pressure, push the O-ring in place.
IMPORTANT: Ensure that the retaining ring is properly seated in the ring groove.
3. Using the J 5403, install the valve retaining ring with the high point of the curved sides against the valve housing.
4. Perform a compressor test. Refer to Compressor Leak Testing. Leak Testing - HVAC System - Automatic