Scan Tool Data Definitions
The SIR Scan Tool Data Definitions contain a brief description of all SIR related parameters available on the scan tool. The list is in the order it appears on the scan tool.Ignition: The scan tool displays 0 - 25.5 Volts. The Ignition represents the system voltage measured by the SDM at its ignition teed.
Driver Senselo: The scan tool displays 0 - 20 Volts. The SDM measures the voltage of the driver frontal low terminal voltage and displays it as Driver Senselo.
Passenger Senselo: The scan tool displays 0 - 20 Volts. The SDM measures the voltage of the passenger frontal low terminal voltage and displays it as Passenger Senselo.
Driver VDIF: The scan tool displays 0 - 500 Millivolts. The SDM measures the difference between driver frontal high and driver frontal low to determine voltage differential.
Passenger VDIF: The scan tool displays 0 - 500 Millivolts. The SDM measures the difference between passenger frontal high and driver frontal low terminals to determine voltage differential.
Driver Energy Reserve: The scan tool displays 0 - 30 Volts. The SDM measures the voltage of the driver frontal energy reserve capacitors inside the SDM and displays it as Driver Energy Reserve.
Passenger Energy Reserve: The scan tool displays 0 - 30 Volts. The SDM measures the voltage of the passenger frontal energy reserve capacitors inside the SDM and displays it as Passenger Energy Reserve.
Warning Lamp ON Time: The scan tool displays 0 - 182 Hours. The SDM measures the continuous warning lamp on time.
Ignition Cycles Lamp ON: The scan tool displays 0 - 125 Cycles. The ignition cycles with the warning lamp ON.
Ignition Cycles Lamp OFF: The scan tool displays 0 - 125 Cycles. The ignition cycles with the warning lamp OFF.
Seatbelt Status: The scan tool displays Buckled or Unbuckled. The SDM receives a discrete signal from the seat belt switch at SDM terminal 1. The SDM sends the seat belt message status over the Class 2 Serial Data Line.