84. Adapter Case Control Valve Assemble
1. Install the PCS (404).
2. Install the PCS retainer (403).
Notice: Refer to Fastener Notice in Service Precautions.
3. Install the PCS bolt (402).
^ Tighten the bolts to 10 Nm (87 inch lbs.).
4. Install the 3-4 accumulator control valve (409).
5. Install the 3-4 accumulator valve (407).
6. Install the 3-4 accumulator valve bore plug (405).
7. Install the feed limit valve spring seat (411) and the feed limit valve (412).
8. Install the feed limit valve spring (410).
9. Install the feed limit valve spring retainer (418).
10. Install the PCS filter (415).
11. Install the PCS plug seal (413) onto the PCS plug (414).
12. Install the PCS plug (414).
13. Install the PCS plug retainer (419).
14. Install the TCC solenoid (416).
15. Install the TCC solenoid bolt (402)
^ Tighten the bolts to 10 Nm (87 inch lbs.).