B1917









Circuit Description:
Inadvertent Power is commanded "ON" and "OFF" by the PZM Inadvertent Power output by, grounding "Inadvertent Power Relay" terminal "c2. The relay is energized and components powered through the relay are supplied battery voltage.

DTC Will Set When:
The "Inadvertent Power Relay" has been commanded "ON" or "OFF" and the PZM feedback does not match that of the commanded state for at least two seconds.

Action Taken (By PZM):
The PZM will continue to command the requested state of the relay until it is achieved or no longer necessary.

DTC Will Clear When:
The PZM feedback matches that of the commanded state for at least two seconds.