Accumulator HVAC: Service and Repair
Accumulator
Remove
1. Recover refrigerant.
2. Accumulator inlet and outlet fittings.
3. Accumulator retention bolts.
4. Accumulator from mounting bracket.
Install
1. Accumulator to mounting bracket.
2. Retention bolts.
Tighten
- Accumulator retention bolts to 4 Nm (35 lb. in.).
3. Inlet and outlet refrigerant lines to accumulator; install new dual O-rings.
Tighten
- Refrigerant line fittings at accumulator to 24 Nm (18 lb. ft.).
4. Evacuate and charge system.
5. Leak test all refrigerant connections.