Battery Negative Cable Disconnection and Connection
Battery Negative Cable Disconnection and Connection
Removal Procedure
1. Turn on the radio and record all of the customer radio station presets.
2. Ensure that all lamps and accessories are turned off.
3. Turn the ignition OFF and remove the ignition key.
4. Remove the battery cover. Refer to Battery Cover Replacement Battery Cover Replacement.
Warning:
Refer to Battery Disconnect Warning Service Precautions.
5. Remove the battery negative cable (1) from the battery.
Installation Procedure
1. Install the battery negative cable (1) to the battery.
Caution:
Refer to Fastener Caution Fastener Caution.
2. Fasten the battery negative cable nut (2) and tighten the nut to 4.5 Nm (40 lb in).
3. Install the battery cover. Refer to Battery Cover Replacement Battery Cover Replacement.
4. Insert the ignition key and turn the ignition to the ON position.
5. Program volatile memory. Refer to Volatile Memory Programming Testing and Inspection.
6. Program all of the customer's radio station presets and set the radio clock to the current time.