64 11 839 Replacing Servodrive for Footwell Flap (Automatic A/C)
64 11 839 Replacing Servodrive For Footwell Flap (automatic A/C)
Necessary preliminary work:
- Remove right glove box with housing
Release screws (1).
Detach actuator drive for footwell flap (2).
Release plug connection (3) and disconnect.
IMPORTANT:
Servomotors must be readdressed in the event of replacement.
Addressing can only be carried out with the BMW diagnosis system.
Service functions:
- Body
- Heating and air conditioning function
- Flap motors
- Readdress flap motors