FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

13 62 601 Replacing Pulse Generator on Left Inlet Camshaft




13 62 601 - Replacing pulse generator on left inlet camshaft (S65)

(cylinder bank 5 to 8)





Necessary preliminary tasks:
- Read out fault memory of DME control unit; if necessary, work through test schedules
- Switch off ignition
- Remove intake filter housing Service and Repair
- Remove left ignition coil cover





Release plug connector (1) and pull off.
Release screw.
Remove pulse generator (2).

Installation Note:
Replace sealing ring and coat with antiseize agent.
Tightening torque, 13 62 5AZ Mechanical Specifications





Note:
Now clear the fault memory.