13 62 607 Replacing Pulse Generator on Transmission
13 62 607 - Replacing pulse generator on transmission (S65)
Necessary preliminary tasks:
- Read out fault memory of DME control unit; if necessary, work through test schedules
- Switch off ignition
- Remove underbody protection
Important!
Oil emerges when the pulse generator is removed. Catch oil in a suitable container and dispose of this oil in accordance with country-specific regulations.
Unlock connector and remove.
Release screw (1).
Remove pulse generator.
Note:
Top up transmission fluid. 00 11 229 Oil Change In Manual Gearbox
Now clear the fault memory.
Add final details to vehicle.