Replacing Rear-End Module Hall Sensor on Partition Wall
54 37 260 - Replacing rear-end module Hall sensor on partition wall
Necessary preliminary tasks:
- Open convertible top compartment lid.
Installation:
- Microencapsulated screws (Loctite) must be replaced and may not be reused
- Screw connection must be completed within 20 minutes (start of curing)
- Microencapsulated screws must not be retightened
- Clean thread of nut beforehand in event of repeated use
Unfasten plug connection (1) and disconnect.
Release screw (2).
Unclip wiring harness.
Feed out Hall sensors.
Installation:
Hall sensor for convertible top cover must be readjusted.
If there is no signal from the Hall sensors, perform the following adjustments:
Adjusting Hall sensor for roof module:
Loosely tighten screws (1) on holder.
Holder should still be able to be slid in order to centre itself.
Stow roof module.
The optimum position of the holders is determined by the retraction of the centering pins into the fastener.
Tighten down screws (1).
Adjusting Hall sensor for convertible top compartment lid:
Insert screw (2) only loosely.
Pull back Hall sensor (1).
Important!
Risk of damage! Switch plate must not rest on Hall sensor.
Close convertible top compartment lid carefully.
Adjust Hall sensor (1) in relation to switch plate.
-A)
- 0.4 mm
Tighten screw (2).
Check function of Hall sensor.