U112A
CDA8 - U112AInformation saved in
DME
Fault code
CDA8 - U112A
Fault text
Message 0x1B4 (status, instrument cluster)
Fault description
Message Monitoring Instrument Pack Status Alive Check
Condition for fault identification
Test condition:
Alive error > 5 (K_CAN_ALIVE_ERR_MAX)
Terminal condition: Terminal 15
Voltage condition:
Battery voltage > 9V (k_can_ed_ub_min)
Condition for fault memory entry
500 ms
Action in service
1. Replace SGM ECU
Fault effect and breakdown warning
All displays in instrument cluster stop operating
Driver information
Warning light:
MIL
Service instruction
none