U0410
27E7 - U0410Information saved in
DME
Fault code
27E7 - U0410
Fault text
Limp-home operation, 100% el. fuel pump activation
Fault description
Invalid Data Received From Fuel Pump Control Module 'A'
Condition for fault identification
Test condition:
pks_can_diag_st == EKP_BEMF_FEHLER
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
1
Action in service
1. Use tester to trigger electric fuel pump module at 100 %
pulse-duty factor
2. If error is logged and pump runs - replace electric fuel
pump module
3. If error is logged and pump does not run - replace pump
Fault effect and breakdown warning
CC status report
Driver information
Warning light:
MIL, CC message
Service instruction
none