P2247
274F - P2247Information saved in
DME
Fault code
274F - P2247
Fault text
Oxygen sensor fault Nernst cable before catalytic converter,
bank 2
Fault description
O2 Sensor Reference Voltage Circuit/Open (Bank 2 Sensor
1)
Condition for fault identification
Test condition:
* Query to controller at MIN limit with oxygen sensor cold
(heater error) => leads to oscillator deactivation
* Oxygen sensor voltage checked for level below the
threshold 98 mV (K_LAVK_OBD_PLAU_UN_SCHW)
Terminal condition: Engine running - Condition idle or part-
load
Voltage condition:
none
Condition for fault memory entry
none
Action in service
1. Check plug and wiring harness on pre-cat oxygen sensor
LSVK B2 (especially UN for Nernst cell voltage supply),
2. If OK, replace oxygen sensor
Fault effect and breakdown warning
MIL lamp on after engine runs 2x /Small influence on
drivability
Driver information
Warning light:
MIL
Service instruction
none