P2198
2727 - P2198Information saved in
DME
Fault code
2727 - P2198
Fault text
Oxygen sensor, plausibility before cat., bank 2
Fault description
O2 Sensor Signal Biased/Stuck Rich (Bank 2 Sensor 1)
Condition for fault identification
Test condition:
Oxygen sensor voltage behind catalytic converter >= 879
mV (K_LAVK_OBD_PLAU_LANK_MAX) (rich) and
lambda factor at front of catalyst >= 1.08
(K_LAVK_OBD_PLAU_LAM_MAGER) (lean) for a total
of 1 (K_LAVK_OBD_PLAU_M_CNT) after a lag period at
onset of operation amounting to 10 sec.
(K_LAVK_OBD_PLAU
Terminal condition: Engine running - Condition idle or part-
load
Voltage condition:
none
Condition for fault memory entry
100 ms
Action in service
1. Clear fault memory, oxygen sensor system test
2. Check plug and wiring harness to pre-cat oxygen sensor
LSVK B2
3. Check induction system and ehaust system for leaks
4. Replace oxygen sensor
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none