P2195
2726 - P2195Information saved in
DME
Fault code
2726 - P2195
Fault text
Oxygen sensor, plausibility before cat., bank 1
Fault description
O2 Sensor Signal Biased/Stuck Lean (Bank 1 Sensor 1)
Condition for fault identification
Test condition:
Oxygen sensor voltage behind catalyst <= 88mV
(K_LAVK_OBD_PLAU_LANK_MIN) (lean) and lambda
factor on front side of catalyst <= 0.92
(K_LAVK_OBD_PLAU_LAM_FETT) (rich) for a total of
1 (K_LAVK_OBD_PLAU_F_CNT) following a lag period
at start of operation amounting to 10 sec.
(K_LAVK_OBD_PLAU_T
Terminal condition: Engine running - Condition idle or part-
load
Voltage condition:
none
Condition for fault memory entry
100 ms
Action in service
1. Clear fault memory, oxygen sensor system test
2. Check plug and wiring harness to pre-cat oxygen sensor
LSVK B1
3. Check induction system and ehaust system for leaks
4. Replace oxygen sensor
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none