P160F
279D - P160FInformation saved in
DME
Fault code
279D - P160F
Fault text
Power management, closed-circuit current violation
Fault description
Powermanagement No-Load Current Error
Condition for fault identification
Test condition:
from IBS data storage: T2histiruh >=
KL_T2RELMAX(T_histsum) or T3histiruh >=
KL_T3RELMAX(T_histsum) or T4histiruh >=
KL_T4RELMAX(T_histsum) or then B_ruhverl -> Error
logged in ECU
Terminal condition: TERM87
Voltage condition:
none
Condition for fault memory entry
200 ms
Action in service
1. Conduct energy diagnosis
2. Check control modules for standby current errors
3. Seek out standby current violators
Fault effect and breakdown warning
CC status report: High battery discharge when parked,
engine start may no longer be possible
Driver information
Warning light:
CC status report
Service instruction
none